Appertization Pilot
Technical Specifications of
Appertization Pilot
Tank
GRC bottom.
Double wall designed for over-pressured water (4 bars), 140°C, soldered and tight triple wall.
2-bar resi
Product Code: ATFE013
(38 Reviews)
Appertization Pilot
Description
Appertization Pilot
Technical Specifications of
Appertization Pilot
Tank
GRC bottom.
Double wall designed for over-pressured water (4 bars), 140°C, soldered and tight triple wall.
2-bar resistant cover closed by 4 bolts.
Opening by swinging the cover.
Temperature probe mounted on the cover.
Agitator mounted on the cover and equipped with a propeller.
The tank is mounted on 3 wheels.
Exhaust valve.
Double wall circuit exhaust valve.
Double wall circuit equipped with a brass brass safety valve.
Stainless steel safety valve on the cover.
Safety key (level IV) preventing the agitator from starting when the cover is open.
Agitator electrical control panel equipped with a timer (sound signal) for cooking time.
Heating unit with over pressured water, 140°C, controlled by an external probe located in the tank.
2 stainless steel hoses (20/27) with 2 x 3-part (3 ½'' and ¾'') fittings at each ends
Essential requirements
Power supply:
6 kW, 380V 3 P (heating unit).
0,25 kW, 380 V 3 P (tank)
Water:
Cold water, DN15, 4 bars.
Permanent exhaust valve DN15, hot water closed to 100°C